The standard values for service illuminance (Em [Lux]), color appearance (F), color rendering group (Ra), and unified glare restriction class (UGRL) according to EN 12464-1 are listed in the table for the various types of interior or activity. The ratings for service illuminance, color rendering group, and direct glare restriction class represent minimum values to be met by the lighting system.
Interiors / Activities |
Em[lx] |
F |
Ra |
UGRL |
Classrooms in primary and secondary schools |
300** |
ww, nw |
80 |
19 |
Classrooms for evening classes and adult education |
500** |
ww, nw |
80 |
19 |
Lecture halls | 500** | ww, nw | 80 | 19 |
Blackboard, demonstration table | 500 | ww, nw | 80 | 19 |
Drawing rooms |
500 |
ww, nw, tw |
80 |
19 |
Drawing rooms for art schools |
750 | T > 5000 K | 90 | 19 |
Rooms for technical drawing | 750 | ww, nw, tw | 80 | 16 |
Practice rooms and laboratories | 500 | ww, nw | 80 | 19 |
Hand workrooms | 500 | ww, nw | 80 | 19 |
Training workshops | 500 | ww, nw | 80 | 19 |
Preparation rooms and workshops | 500 | ww, nw | 80 | 22 |
Music practice rooms | 300 | ww, nw | 80 | 19 |
Computer practice rooms | 300 | ww, nw | 80 | 19*** |
Language laboratories | 300 | ww, nw | 80 | 19 |
Common areas for pupils / students and common areas | 200 | ww, nw | 80 | 22 |
Staff rooms | 300 | ww, nw | 80 | 19 |
Libraries: Bookshelves | 200 | ww, nw | 80 | 19 |
Libraries: Reading areas | 500 | ww, nw | 80 | 19 |
Course material collection | 100 | ww, nw | 80 | 25 |
Sport halls, gymnasia, indoor swimming pools | 300 | ww, nw | 80 | 22 |
Corridors | 200 | ww, nw | 80 | 22 |
Corridors, circulation areas
|
100 | ww, nw | 80 | 25 |
Stairs | 150 | ww, nw | 80 | 25 |
School canteens | 200 | ww, nw | 80 | 22 |
Kitchens | 500 | ww, nw | 80 | 22 |