The standard values for service illuminance (Em [Lux]), color appearance (F), color rendering group (Ra), and unified glare restriction class (UGRL) according to EN 12464-1 are listed in the table for the various types of interior or activity. The ratings for service illuminance, color rendering group, and direct glare restriction class represent minimum values to be met by the lighting system.


Interiors / Activities

Em[lx]

F

Ra

UGRL

Accessible underground conduits, conveyors, cellars, etc.

50

ww, nw

20

-

Platforms

100

ww, nw

40

25

Sand moulding

200

ww, nw

80

25

Cleaning

200

ww, nw

80

25

Furnace and mixer workstations

200

ww, nw

80

25

Casting bays

300

ww, nw

80

25

Knocking out

200

ww, nw

80

25

Machine moulding

200

ww, nw

80

25

Hand and core moulding

300

ww, nw

80

25

Pressure foundry

300

ww, nw

80

25

Model workshop

500

ww, nw

80

22